CQB-L Vertical Magnetic Pipeline Pump for Chemical Transfer

CQB-L Vertical Magnetic Pipeline Pump for Chemical Transfer

CQB-L Vertical Inline Magnetic Pump | Seal-less inline mag-drive chemical pump

  • Seal-less mag-drive: Leak-free, no mechanical seal.
  • Vertical inline fit: Compact pipeline installation.
  • Corrosion-resistant wet end: Materials matched to media.
  • Stable duty: Smooth transfer/circulation.

Product Overview

CQB-L Vertical Magnetic Pipeline Pump is a vertical, sealless magnetic drive centrifugal pipeline pump designed with magnetic coupling and corrosion-resistant wetted materials for leak-free chemical media transfer.

It eliminates dynamic shaft seal leakage, reducing safety hazards and maintenance in corrosive, toxic, flammable or volatile fluid systems.

It is suitable for vertical chemical transfer applications in petroleum, chemical, pharmaceutical, electroplating and related industries requiring compact, leak-free operation.

Model selection shall be determined based on hydraulic duty, material compatibility, and system pressure requirements.

Model Designation

CQB-L Vertical Magnetic Pipeline Pump for Chemical Transfer

Applications

Typical Operating Scenarios

• Vertical pipeline transfer of corrosive liquids in chemical process lines
• Transfer of acid and alkali media in sealed industrial systems
• Hazardous fluid handling in petrochemical plants
• Electroplating and surface treatment fluid circulation
• Compact vertical pumping applications with limited footprint

Engineering Advantages

Structural Design Logic + Engineering Result

CQB-L pumps integrate a vertical pipeline magnetic drive with permanent magnet coupling and static isolation sleeve to transmit torque without dynamic seals, creating a completely enclosed flow path that eliminates the primary leakage risk of conventional mechanical seals. Corrosion-resistant wetted components (pump body, impeller, isolation sleeve) and wear-resistant shaft sleeves and bearings enhance service life and operational reliability. Vertical compact structure reduces footprint and simplifies installation.

Magnetic drive and sealed isolation structure ensure leak-free operation, corrosion resistance and reliable vertical pipeline chemical transfer.

System Components

CQB-L Vertical Magnetic Pipeline Pump mainly consists of:

  • Pump casing (stainless steel corrosion-resistant)
  • Impeller
  • Permanent magnet coupling (inner & outer rotors)
  • Isolation sleeve
  • Shaft sleeve (SiC/WC options)
  • Sliding bearing (M106K graphite)
  • Bearing housing
  • Bracket/base frame
  • Motor

Technical Specifications

Service Conditions

• Medium: Corrosive liquids (acids, alkalis, toxic, flammable) compatible with stainless steel and isolation materials
• Solid content: Low, non-abrasive
• Installation: Vertical inline configuration
• Operation: Continuous duty

Operating Conditions

Parameter Value
Flow rate 3.2 – 100 m³/h
Head 8 – 80 m
Speed 2900 rpm
Power range 0.75 – 45 kW
Liquid temperature ≤ 100°C
Working pressure ≤ 1.6 MPa

(values based on typical CQB-L series information)
Detailed parameter tables are provided below.

Specifications & Installation

Outline Drawing

CQB-L Vertical Magnetic Pipeline Pump Structure Diagram

Performance Data

No. Name No. Name
1 Pump casing 8 Pump shaft
2 Impeller 9 Containment shell bearing seat
3 Impeller nut 10 Inner magnetic rotor
4 Seal ring 11 Thrust ring
5 Bearing housing 12 Outer magnet assembly
6 Sliding bearing seat 13 Bracket
7 Shaft sleeve 14 Motor

Performance Parameters

Model
Flow Q
(m³/h)
Head
(m)
Speed n
(r/min)
Efficiency η
(%)
Motor power
(kW)
CQB32-125L 3.2 20 2900 30 1.1
CQB32-160L 3.2 32 2900 28 1.5
CQB40-105L 6.3 12.5 2900 39 1.1
CQB40-125L 6.3 20 2900 35 1.1
CQB40-160L 6.3 32 2900 32 2.2
CQB40-200L 6.3 50 2900 25 4
CQB50-85L 12.5 8 2900 49 0.75
CQB50-105L 12.5 12.5 2900 47 1.1
CQB50-125L 12.5 20 2900 39 3
CQB50-160L 12.5 32 2900 39 4
CQB50-200L 12.5 50 2900 31 7.5
CQB50-250L 12.5 80 2900 25 15
CQB65-125L 25 20 2900 45 5.5
CQB65-160L 25 32 2900 45 7.5
CQB65-200L 25 50 2900 35 15
CQB65-250L 25 80 2900 37 18.5
CQB80-125L 50 20 2900 55 7.5
CQB80-160L 50 32 2900 55 11
CQB80-200L 50 50 2900 50 18.5
CQB100-125L 100 20 2900 56 11
CQB100-160L 100 32 2900 55 18.5
CQB100-200L 100 50 2900 53 30
CQB100-250L 100 80 2900 48 45

How to Select a Pump Model

  1. Determine required flow rate and total head including vertical lift.
  2. Verify chemical compatibility with wetted stainless steel and isolation sleeve materials.
  3. Confirm operating temperature ≤ 100°C and pressure ≤ 1.6 MPa.
  4. Choose shaft sleeve and bearing materials based on abrasion and corrosive severity.
  5. Ensure vertical installation space and flange size match pipeline system.
Model selection must be based on hydraulic duty, chemical compatibility, and installation conditions.

Engineering Notes

• Magnetic drive eliminates dynamic seals, improving safety in hazardous media service.
• Vertical pipeline orientation saves footprint but requires proper alignment and support.
• Silicon carbide or tungsten carbide shaft sleeves enhance abrasion resistance.
• Sliding bearings must be properly lubricated by the pumped medium.

Compliance & Quality Assurance

• Factory hydraulic performance testing and curve verification
• Material traceability of stainless steel and wear components
• Isolation sleeve pressure integrity testing
• Magnetic coupling torque verification
• Optional third-party inspection per customer requirements

Safety Notice

• Do not operate under dry-running condition.
• Ensure system is properly vented and primed before startup.
• Do not exceed rated temperature or pressure.
• Disconnect power before performing maintenance.

OEM & Custom

This pump series supports engineered configuration and duty-based matching. Technical adjustments can be made according to system requirements and installation conditions.

Available options include:
• Motor voltage & frequency
• Wetted parts material selection (304/316/316L)
• Shaft sleeve material (SiC/WC)
• Bearing enhancements
• Explosion-proof motor options

Configuration is determined based on duty point and project specifications.

FAQs

Q1: Can CQB-L operate under variable frequency drive (VFD) control?
A: Yes, within rated speed and torque conditions.

Q2: What is the maximum working pressure?
A: Maximum working pressure is ≤ 1.6 MPa.

Q3: Does the pump use mechanical seals?
A: No, it uses magnetic drive with static isolation sleeve for sealing.

Q4: What materials are available for over-flow parts?
A: Stainless steel (304, 316, 316L) wetted components.

Q5: Is it suitable for flammable or toxic liquids?
A: Yes, leak-free magnetic design enables handling hazardous media.

Q6: What is the allowable liquid temperature?
A: Up to approximately 100°C depending on material selection.

Q7: Can the pump be installed in space-limited areas?
A: Yes, vertical inline orientation reduces footprint.