Product Overview
LG-B Facility Dismantle Vertical Multistage Centrifugal Pump is a vertical multistage centrifugal pump with back-pull-out dismantling structure designed for high-rise water supply and pressure boosting applications.
It solves maintenance difficulty in confined pump rooms by allowing mechanical seal and rotating assembly removal without dismantling pipeline connections.
It is applied in high-rise building water supply, HVAC circulation systems, industrial process boosting, and municipal pressure regulation stations.
Model Designation

Applications
Typical Operating Scenarios
• High-rise domestic water boosting with vertical pipeline layout
• HVAC chilled and hot water circulation in equipment rooms with limited space
• Industrial clean water transfer requiring stable high head output
• Municipal pressure stabilization stations with inline vertical installation
• Replacement projects requiring minimal piping modification
Engineering Advantages
Structural Design Logic & Engineering Outcome
• Back pull-out dismantling structure enables seal and rotor maintenance without disturbing inlet/outlet pipelines.
• Vertical multistage hydraulic design provides high head under compact footprint.
• Coaxial inlet and outlet reduce pipeline stress and simplify installation alignment.
• Cartridge mechanical seal configuration improves serviceability and operational stability.
System Components
LG-B Facility Dismantle Vertical Multistage Centrifugal Pump :
• Pump head assembly (stage casing and impellers)
• Back pull-out rotating assembly
• Mechanical seal cartridge
• Motor and coupling system
• Base and vertical support structure
Technical Specifications
Service Conditions
Suitable for clean water or liquids with physical and chemical properties similar to water.
Not suitable for flammable, explosive, or corrosive media unless specially configured.
Operating Conditions
Flow Rate: 3 – 150 m³/h
Head: 20 – 200 m
Power Range: 0.75 – 132 kW
Speed: 2900 rpm
Liquid Temperature: ≤ 80°C (Standard) / ≤ 105°C (Hot Water Version)
Working Pressure: ≤ 2.5 MPa
Detailed parameter tables are provided below.
Installation & Dimensions
Outline Drawing

Performance Data
| No. | Name | Material / Model | No. | Name | Material / Model |
| 1 | Motor | Y Series (V5), 2-Pole | 9 | Shaft Sleeve | Q235 |
| 2 | Motor Support | HT200 | 10 | Middle Section | HT200 |
| 3 | Coupling | HT200 | 11 | Guide Vane | HT200 |
| 4 | Mechanical Seal Gland | HT200 | 12 | Impeller | HT200 |
| 5 | Exhaust Valve | Brass Alloy | 13 | Shaft | 45 / 2Cr13 |
| 6 | Mechanical Seal | 120A | 14 | Bearing | Tin Bronze |
| 7 | Final Guide Vane | HT200 | 15 | Inlet Section | HT200 |
| 8 | Discharge Section | HT200 |
Performance Parameters
| Model | Stages | Flow Rate | Head | Speed | Motor Power | Efficiency | Weight | NPSHr |
| (m3/h) | (M) | (r/min) | (kw) | (%) | Kg | (NPSH)r(m) | ||
| 25LG(R)3-10*2 | 2 | 3 | 20 | 2900 | 0.75 | 42 | 70 | 2.0 |
| 25LG(R)3-10*3 | 3 | 3 | 30 | 2900 | 1.1 | 42 | 74 | 2.0 |
| 25LG(R)3-10*4 | 4 | 3 | 40 | 2900 | 1.5 | 42 | 85 | 2.0 |
| 25LG(R)3-10*5 | 5 | 3 | 50 | 2900 | 1.5 | 42 | 89 | 2.0 |
| 25LG(R)3-10*6 | 6 | 3 | 60 | 2900 | 2.2 | 42 | 100 | 2.0 |
| 25LG(R)3-10*7 | 7 | 3 | 70 | 2900 | 2.2 | 42 | 104 | 2.0 |
| 25LG(R)3-10*8 | 8 | 3 | 80 | 2900 | 2.2 | 42 | 108 | 2.0 |
| 25LG(R)3-10*9 | 9 | 3 | 90 | 2900 | 2.2 | 42 | 112 | 2.0 |
| 25LG(R)3-10*10 | 10 | 3 | 100 | 2900 | 3 | 42 | 125 | 2.0 |
| 25LG(R)3-10*11 | 11 | 3 | 110 | 2900 | 3 | 42 | 129 | 2.0 |
| 25LG(R)3-10*12 | 12 | 3 | 120 | 2900 | 4 | 42 | 145 | 2.0 |
| 25LG(R)3-10*13 | 13 | 3 | 130 | 2900 | 4 | 42 | 149 | 2.0 |
| 25LG(R)3-10*14 | 14 | 3 | 140 | 2900 | 4 | 42 | 153 | 2.0 |
| 25LG(R)3-10*15 | 15 | 3 | 150 | 2900 | 4 | 42 | 157 | 2.0 |
| Model | Stages | Flow Rate | Head | Speed | Motor Power | Efficiency | Weight | NPSHr |
| (m3/h) | (M) | (r/min) | (kw) | (%) | Kg | (NPSH)r(m) | ||
| 32LG(R)6.5-15*2 | 2 | 6.5 | 30 | 2900 | 1.5 | 53 | 90 | 2.4 |
| 32LG(R)6.5-15*3 | 3 | 6.5 | 45 | 2900 | 2.2 | 53 | 100 | 2.4 |
| 32LG(R)6.5-15*4 | 4 | 6.5 | 60 | 2900 | 3 | 53 | 115 | 2.4 |
| 32LG(R)6.5-15*5 | 5 | 6.5 | 75 | 2900 | 4 | 53 | 135 | 2.4 |
| 32LG(R)6.5-15*6 | 6 | 6.5 | 90 | 2900 | 4 | 53 | 142 | 2.4 |
| 32LG(R)6.5-15*7 | 7 | 6.5 | 105 | 2900 | 5.5 | 53 | 175 | 2.4 |
| 32LG(R)6.5-15*8 | 8 | 6.5 | 120 | 2900 | 5.5 | 53 | 182 | 2.4 |
| 32LG(R)6.5-15*9 | 9 | 6.5 | 135 | 2900 | 5.5 | 53 | 190 | 2.4 |
| 32LG(R)6.5-15*10 | 10 | 6.5 | 150 | 2900 | 7.5 | 53 | 210 | 2.4 |
| 40LG(R)12-15*2 | 2 | 12 | 30 | 2900 | 2.2 | 60 | 90 | 2.9 |
| 40LG(R)12-15*3 | 3 | 12 | 45 | 2900 | 3 | 60 | 105 | 2.9 |
| 40LG(R)12-15*4 | 4 | 12 | 60 | 2900 | 4 | 60 | 130 | 2.9 |
| 40LG(R)12-15*5 | 5 | 12 | 75 | 2900 | 5.5 | 60 | 155 | 2.9 |
| 40LG(R)12-15*6 | 6 | 12 | 90 | 2900 | 5.5 | 60 | 163 | 2.9 |
| 40LG(R)12-15*7 | 7 | 12 | 105 | 2900 | 7.5 | 60 | 180 | 2.9 |
| 40LG(R)12-15*8 | 8 | 12 | 120 | 2900 | 7.5 | 60 | 190 | 2.9 |
| 40LG(R)12-15*9 | 9 | 12 | 135 | 2900 | 11 | 60 | 215 | 2.9 |
| 40LG(R)12-15*10 | 10 | 12 | 150 | 2900 | 11 | 60 | 225 | 2.9 |
| Model | Stages | Flow Rate | Head | Speed | Motor Power | Efficiency | Weight | NPSHr |
| (m3/h) | (M) | (r/min) | (kw) | (%) | Kg | (NPSH)r(m) | ||
| 50LG(R)24-20*2 | 2 | 24 | 40 | 2900 | 5.5 | 69 | 160 | 3.2 |
| 50LG(R)24-20*3 | 3 | 24 | 60 | 2900 | 7.5 | 69 | 180 | 3.2 |
| 50LG(R)24-20*4 | 4 | 24 | 80 | 2900 | 11 | 69 | 250 | 3.2 |
| 50LG(R)24-20*5 | 5 | 24 | 100 | 2900 | 11 | 69 | 260 | 3.2 |
| 50LG(R)24-20*6 | 6 | 24 | 120 | 2900 | 15 | 69 | 280 | 3.2 |
| 50LG(R)24-20*7 | 7 | 24 | 140 | 2900 | 15 | 69 | 290 | 3.2 |
| 50LG(R)24-20*8 | 8 | 24 | 160 | 2900 | 18.5 | 69 | 315 | 3.2 |
| 65LG(R)36-20*2 | 2 | 36 | 40 | 2900 | 7.5 | 72 | 170 | 3.4 |
| 65LG(R)36-20*3 | 3 | 36 | 60 | 2900 | 11 | 72 | 230 | 3.4 |
| 65LG(R)36-20*4 | 4 | 36 | 80 | 2900 | 15 | 72 | 250 | 3.4 |
| 65LG(R)36-20*5 | 5 | 36 | 100 | 2900 | 18.5 | 72 | 280 | 3.4 |
| 65LG(R)36-20*6 | 6 | 36 | 120 | 2900 | 22 | 72 | 330 | 3.4 |
| 65LG(R)36-20*7 | 7 | 36 | 140 | 2900 | 22 | 72 | 345 | 3.4 |
| 65LG(R)36-20*8 | 8 | 36 | 160 | 2900 | 30 | 72 | 395 | 3.4 |
| Model | Stages | Flow Rate | Head | Speed | Motor Power | Efficiency | Weight | NPSHr |
| (m3/h) | (M) | (r/min) | (kw) | (%) | Kg | (NPSH)r(m) | ||
| 80LG(R)50-20*2 | 2 | 50 | 40 | 2900 | 11 | 73 | 250 | 3.4 |
| 80LG(R)50-20*3 | 3 | 50 | 60 | 2900 | 15 | 73 | 280 | 3.4 |
| 80LG(R)50-20*4 | 4 | 50 | 80 | 2900 | 18.5 | 73 | 310 | 3.4 |
| 80LG(R)50-20*5 | 5 | 50 | 100 | 2900 | 22 | 73 | 360 | 3.4 |
| 80LG(R)50-20*6 | 6 | 50 | 120 | 2900 | 30 | 73 | 440 | 3.4 |
| 80LG(R)50-20*7 | 7 | 50 | 140 | 2900 | 30 | 73 | 460 | |
| 80LG(R)50-20*8 | 8 | 50 | 160 | 2900 | 37 | 73 | 490 | |
| 100LG72-20*2 | 2 | 72 | 40 | 2900 | 11 | 73 | 260 | 3.5 |
| 100LG72-20*3 | 3 | 72 | 60 | 2900 | 18.5 | 73 | 290 | 3.5 |
| 100LG72-20*4 | 4 | 72 | 80 | 2900 | 22.0 | 73 | 380 | 3.5 |
| 100LG72-20*5 | 5 | 72 | 100 | 2900 | 30.0 | 73 | 450 | 3.5 |
| 100LG72-20*6 | 6 | 72 | 120 | 2900 | 37.0 | 73 | 470 | 3.5 |
| 100LG72-20*7 | 7 | 72 | 140 | 2900 | 45.0 | 73 | 520 | 3.5 |
| 100LG72-20*8 | 8 | 72 | 160 | 2900 | 45.0 | 73 | 540 | 3.5 |
| 100LG72-20*9 | 9 | 72 | 180 | 2900 | 55.0 | 73 | 3.5 | |
| Model | Stages | Flow Rate | Head | Speed | Motor Power | Efficiency | Weight | NPSHr |
| (m3/h) | (M) | (r/min) | (kw) | (%) | Kg | (NPSH)r(m) | ||
| 100LG100-20*2 | 2 | 100 | 40 | 2900 | 18.5 | 76 | 3.7 | |
| 100LG100-20*3 | 3 | 100 | 60 | 2900 | 30 | 76 | 3.7 | |
| 100LG100-20*4 | 4 | 100 | 80 | 2900 | 37 | 76 | 3.7 | |
| 100LG100-20*5 | 5 | 100 | 100 | 2900 | 45 | 76 | 3.7 | |
| 100LG100-20*6 | 6 | 100 | 120 | 2900 | 55 | 76 | 3.7 | |
| 100LG100-20*7 | 7 | 100 | 140 | 2900 | 75 | 76 | 3.7 | |
| 100LG100-20*8 | 8 | 100 | 160 | 2900 | 75 | 76 | 3.7 | |
| 150LG150-20*2 | 2 | 150 | 40 | 2900 | 30 | 77 | 4.1 | |
| 150LG150-20*3 | 3 | 150 | 60 | 2900 | 37 | 77 | 4.1 | |
| 150LG150-20*4 | 4 | 150 | 80 | 2900 | 45 | 77 | 4.1 | |
| 150LG150-20*5 | 5 | 150 | 100 | 2900 | 55 | 77 | 4.1 | |
| 150LG150-20*6 | 6 | 150 | 120 | 2900 | 75 | 77 | 4.1 | |
| 150LG150-20*7 | 7 | 150 | 140 | 2900 | 90 | 77 | 4.1 | |
| 150LG150-20*8 | 8 | 150 | 160 | 2900 | 90 | 77 | 4.1 | |
| 150LG150-20*9 | 9 | 150 | 180 | 2900 | 110 | 77 | 4.1 | |
| 150LG150-20*10 | 10 | 150 | 200 | 2900 | 132 | 77 | 4.1 |
Installation Diagram

Performance Parameters(2)
|
Model |
Stages | L | H | H1 | H2 | B | b | n-φd | Inlet Flange | Outlet Flange | ||||||
| Dj | Djn | Dj2 | n-dj | Dc | Dcn | Dc2 | n-φdc | |||||||||
| 25LG(R)3-10 | 2 | 130 | 630 | 85 | 180 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 3 | 130 | 670 | 85 | 220 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 4 | 130 | 710 | 85 | 260 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 5 | 130 | 755 | 85 | 305 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 6 | 130 | 825 | 85 | 340 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 7 | 130 | 865 | 85 | 380 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 8 | 130 | 900 | 85 | 425 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 9 | 130 | 945 | 85 | 460 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 10 | 130 | 1020 | 85 | 500 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 11 | 130 | 1060 | 85 | 540 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 12 | 130 | 1120 | 85 | 580 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 13 | 130 | 1160 | 85 | 620 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 14 | 130 | 1200 | 85 | 660 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
| 25LG(R)3-10 | 15 | 130 | 1240 | 85 | 700 | 230 | 190 | 4-φ18 | 115 | 25 | 85 | 4-M12 | 115 | 25 | 85 | 4-φ14 |
|
Model |
Stages | L | H | H1 | H2 | B | b | n-φd | Inlet Flange | Outlet Flange | ||||||
| Dj | Djn | Dj2 | n-dj | Dc | Dcn | Dc2 | n-φdc | |||||||||
| 32LG(R)6.5-15 | 2 | 145 | 665 | 63 | 179 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 3 | 145 | 740 | 63 | 229 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 4 | 145 | 825 | 63 | 279 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 5 | 145 | 895 | 63 | 329 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 6 | 145 | 945 | 63 | 379 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 7 | 145 | 1070 | 63 | 429 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 8 | 145 | 1120 | 63 | 479 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 9 | 145 | 1170 | 63 | 529 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 32LG(R)6.5-15 | 10 | 145 | 1220 | 63 | 579 | 260 | 220 | 4-φ18 | 140 | 32 | 100 | 4-M16 | 140 | 32 | 100 | 4-φ18 |
| 40LG(R)12-15 | 2 | 145 | 710 | 70 | 193 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 3 | 145 | 800 | 70 | 251 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 4 | 145 | 880 | 70 | 309 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 5 | 145 | 1015 | 70 | 367 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 6 | 145 | 1075 | 70 | 425 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 7 | 145 | 1170 | 70 | 483 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 8 | 145 | 1230 | 70 | 541 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 9 | 145 | 1410 | 70 | 599 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
| 40LG(R)12-15 | 10 | 145 | 1465 | 70 | 657 | 260 | 220 | 4-φ18 | 150 | 40 | 110 | 4-M16 | 150 | 40 | 110 | 4-φ18 |
|
Model |
Stages | L | H | H1 | H2 | B | b | n-φd | Inlet Flange | Outlet Flange | ||||||
| Dj | Djn | Dj2 | n-dj | Dc | Dcn | Dc2 | n-φdc | |||||||||
| 50LG(R)24-20 | 2 | 180 | 885 | 80 | 214 | 300 | 248 | 4-φ23 | 165 | 50 | 125 | 4-M16 | 165 | 50 | 125 | 4-φ18 |
| 50LG(R)24-20 | 3 | 180 | 985 | 80 | 273 | 300 | 248 | 4-φ23 | 165 | 50 | 125 | 4-M16 | 165 | 50 | 125 | 4-φ18 |
| 50LG(R)24-20 | 4 | 180 | 1145 | 80 | 332 | 300 | 248 | 4-φ23 | 165 | 50 | 125 | 4-M16 | 165 | 50 | 125 | 4-φ18 |
| 50LG(R)24-20 | 5 | 180 | 1210 | 80 | 391 | 300 | 248 | 4-φ23 | 165 | 50 | 125 | 4-M16 | 165 | 50 | 125 | 4-φ18 |
| 50LG(R)24-20 | 6 | 180 | 1275 | 80 | 450 | 300 | 248 | 4-φ23 | 165 | 50 | 125 | 4-M16 | 165 | 50 | 125 | 4-φ18 |
| 50LG(R)24-20 | 7 | 180 | 1340 | 80 | 509 | 300 | 248 | 4-φ23 | 165 | 50 | 125 | 4-M16 | 165 | 50 | 125 | 4-φ18 |
| 50LG(R)24-20 | 8 | 180 | 1450 | 80 | 568 | 300 | 248 | 4-φ23 | 165 | 50 | 125 | 4-M16 | 165 | 50 | 125 | 4-φ18 |
| 65LG(R)36-20 | 2 | 180 | 965 | 90 | 245 | 300 | 248 | 4-φ23 | 185 | 65 | 145 | 4-M16 | 185 | 65 | 145 | 4-φ18 |
| 65LG(R)36-20 | 3 | 180 | 1120 | 90 | 304 | 300 | 248 | 4-φ23 | 185 | 65 | 145 | 4-M16 | 185 | 65 | 145 | 4-φ18 |
| 65LG(R)36-20 | 4 | 180 | 1185 | 90 | 363 | 300 | 248 | 4-φ23 | 185 | 65 | 145 | 4-M16 | 185 | 65 | 145 | 4-φ18 |
| 65LG(R)36-20 | 5 | 180 | 1295 | 90 | 422 | 300 | 248 | 4-φ23 | 185 | 65 | 145 | 4-M16 | 185 | 65 | 145 | 4-φ18 |
| 65LG(R)36-20 | 6 | 180 | 1390 | 90 | 481 | 300 | 248 | 4-φ23 | 185 | 65 | 145 | 4-M16 | 185 | 65 | 145 | 4-φ18 |
| 65LG(R)36-20 | 7 | 180 | 1455 | 90 | 540 | 300 | 248 | 4-φ23 | 185 | 65 | 145 | 4-M16 | 185 | 65 | 145 | 4-φ18 |
| 65LG(R)36-20 | 8 | 180 | 1615 | 90 | 599 | 300 | 248 | 4-φ23 | 185 | 65 | 145 | 4-M16 | 185 | 65 | 145 | 4-φ18 |
|
Model |
Stages | L | H | H1 | H2 | B | b | n-φd | Inlet Flange | Outlet Flange | ||||||
| Dj | Djn | Dj2 | n-dj | Dc | Dcn | Dc2 | n-φdc | |||||||||
| 80LG(R)50-20 | 2 | 187 | 965 | 112 | 301 | 315 | 272 | 4-φ23 | 200 | 80 | 160 | 8-M16 | 200 | 80 | 160 | 8-φ18 |
| 80LG(R)50-20 | 3 | 187 | 1195 | 112 | 379 | 315 | 272 | 4-φ23 | 200 | 80 | 160 | 8-M16 | 200 | 80 | 160 | 8-φ18 |
| 80LG(R)50-20 | 4 | 187 | 1270 | 112 | 457 | 315 | 272 | 4-φ23 | 200 | 80 | 160 | 8-M16 | 200 | 80 | 160 | 8-φ18 |
| 80LG(R)50-20 | 5 | 187 | 1395 | 112 | 535 | 315 | 272 | 4-φ23 | 200 | 80 | 160 | 8-M16 | 200 | 80 | 160 | 8-φ18 |
| 80LG(R)50-20 | 6 | 187 | 1505 | 112 | 613 | 315 | 272 | 4-φ23 | 200 | 80 | 160 | 8-M16 | 200 | 80 | 160 | 8-φ18 |
| 80LG(R)50-20 | 7 | 187 | 1675 | 112 | 691 | 315 | 272 | 4-φ23 | 200 | 80 | 160 | 8-M16 | 200 | 80 | 160 | 8-φ18 |
| 80LG(R)50-20 | 8 | 187 | 1755 | 112 | 769 | 315 | 272 | 4-φ23 | 200 | 80 | 160 | 8-M16 | 200 | 80 | 160 | 8-φ18 |
| 100LG72-20 | 2 | 187 | 1185 | 122 | 343 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
| 100LG72-20 | 3 | 187 | 1270 | 122 | 432 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
| 100LG72-20 | 4 | 187 | 1390 | 122 | 521 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
| 100LG72-20 | 5 | 187 | 1580 | 122 | 610 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
| 100LG72-20 | 6 | 187 | 1655 | 122 | 699 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
| 100LG72-20 | 7 | 187 | 1800 | 122 | 788 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
| 100LG72-20 | 8 | 187 | 1900 | 122 | 877 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
| 100LG72-20 | 9 | 187 | 2100 | 122 | 966 | 315 | 272 | 4-φ23 | 220 | 100 | 180 | 8-M16 | 220 | 100 | 180 | 8-φ18 |
Installation Diagram(2)
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Installation Diagram(3)
|
|
|||||||||||||||||||||||||||||||||||||
Performance Data(2)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
How to Select a Pump Model
• Determine required duty point (flow rate and total dynamic head) based on system hydraulic calculation.
• Verify installation space to confirm vertical structure compatibility.
• Evaluate maintenance accessibility requirements to confirm need for dismantle structure.
• Confirm allowable system pressure to select appropriate stage number.
Engineering Notes
• Pump should operate near rated duty point to ensure hydraulic efficiency.
• Adequate NPSH must be ensured to prevent cavitation in high-temperature systems.
• Foundation rigidity must support vertical load and motor weight.
• Pipeline stress should not be transferred to pump casing.
Compliance & Quality Assurance
• Factory hydraulic performance test before shipment
• Dynamic balance test for rotating assembly
• Pressure casing hydrostatic test
• Mechanical seal inspection and leakage verification
• Material certification traceability for wetted components
Safety Notice
• Do not operate under dry-running condition.
• Ensure suction priming before startup.
• Disconnect power before mechanical dismantling.
• Do not exceed rated working pressure.
OEM & Customization
This pump series supports engineered configuration and duty-based matching. Technical adjustments can be made according to system requirements and installation conditions.
Available options include:
• Motor voltage & frequency
• Mechanical seal type and configuration
• Wetted parts material selection
• Surface coating and corrosion protection
Configuration is determined based on duty point and project specifications.
FAQs
Q1: Can the pump operate under VFD control?
Yes, frequency control is compatible for variable flow regulation.
Q2: What is the allowable maximum working pressure?
Maximum allowable working pressure is ≤ 2.5 MPa depending on configuration.
Q3: What is the maximum liquid temperature?
Standard configuration supports ≤ 120°C.
Q4: Is the mechanical seal replaceable without removing piping?
Yes, the back pull-out structure allows maintenance without pipeline dismantling.
Q5: What is the required NPSH margin?
NPSH requirement depends on model size and operating flow; refer to performance curve.
Q6: What installation orientation is required?
The pump must be installed vertically with aligned coaxial pipeline connection.



