LW/WL Vertical Sewage Pump | Non-Clogging, High Efficiency

LW/WL Vertical Sewage Pump | Non-Clogging, High Efficiency

LW/WL Vertical Sewage Pump | Non-clog, anti-winding wastewater transfer with auto install/control

  • Non-clog / anti-winding hydraulics: Handles solids and long-fiber debris with stable passage.
  • Vertical dry-pit layout: Space-efficient installation, suitable for pump rooms and station setups.
  • Impeller & seal package: Optimized impeller with upgraded mechanical sealing for wastewater duty.
  • Automation-ready operation: Supports automatic installation and automatic control for unattended service.

Product Overview

The LW/ WL Non-Clogging Vertical Sewage Pump is a vertical wastewater pump specifically designed for handling media containing solid particles and long fiber materials. This series is developed for actual sewage and drainage applications, offering reliable non-clogging performance and stable solid-liquid transfer capabilities, ideal for continuous operation in wastewater treatment and sewage treatment systems.

The pump features a specialized non-clogging impeller design and robust mechanical seals, ensuring stable and reliable operation when pumping media containing solids and fibrous impurities.

Model Designation

LWWL Vertical Sewage Pumptype

Key Features

  • Single or double-channel impeller design, significantly improving the ability to handle solid particles and fibrous media, reducing clogging risks.

  • Mechanical seals using advanced friction pair materials, operating in an oil chamber to enhance sealing reliability and ensure continuous operation.

  • Compact structure with low noise, small footprint, and easy maintenance, facilitating component replacement.

  • Optional automatic control system that enables automatic start/stop based on liquid level changes, reducing manual intervention.

  • Multiple installation options available, allowing installation and maintenance without entering the sewage pit.

  • Safe operation within the design range, effectively preventing motor overload.

  • Outdoor-rated motor configuration allows the pump to be directly installed outdoors without the need for a pump room, reducing overall installation and construction costs.

Engineering Summary

The LW/ WL Series Non-Clogging Vertical Sewage Pump uses an optimized design focusing on high-efficiency hydraulic performance and reliable long-term operation. The single-channel or double-channel impeller design, coupled with a well-engineered flow path geometry, effectively enhances solid particle handling capacity and reduces clogging risks. With mechanical seals made from abrasion-resistant hard alloys, the pump guarantees long-lasting, stable operation, especially in harsh sewage conditions. The pump is ideal for various applications, offering an efficient, compact solution that ensures reliable service in complex drainage systems.

Typical Applications

The LW/WL  Non-Clogging Vertical Sewage Pump is suitable for the following applications:

  • Industrial wastewater discharge and treatment systems

  • Residential sewage pumping stations

  • Municipal sewage treatment plant discharge systems

  • Civil defense and emergency drainage systems

  • Sewage discharge in hospitals, hotels, and public buildings

  • Municipal engineering and construction site drainage

  • Auxiliary dewatering in mining operations

  • Rural biogas pits and agricultural irrigation

This pump is designed for handling sewage, wastewater with solid particles, sludge, wood chips, starch, minerals, and other suspended solids, as well as clean water or mildly corrosive liquids.

System & Operation

Components & Supply

  • Single or double-channel impeller design, improving the ability to handle solid particles and fibrous media.

  • Abrasion-resistant hard alloy mechanical seals, ensuring long-term reliable performance.

  • Compact structure with low noise, small footprint, and easy maintenance, enabling quick component replacement.

  • Optional fully automatic control panel for start/stop operation based on liquid level changes, reducing the need for manual intervention.

Technical Specifications

Operating Conditions

  • Liquid Temperature:
    • Standard Pump: ≤ 40°C
    • Hot Water Pump: ≤ 80°C (special applications can meet up to 120°C)

  • Ambient Temperature: ≤ +40°C

  • Maximum Working Pressure: 10 bar

  • Maximum Allowable Inlet Pressure: Limited by system working pressure

  • Fluid Requirements:
    • Clean, low-viscosity, non-flammable, sulfur-free liquids, free from solid particles or fibers
    • Suitable for pumping mineral water, softened water, purified water, light oils, and mild chemical fluids
    • If the liquid’s density or viscosity exceeds that of water, a higher-rated motor should be selected
    • The pump’s suitability for specific liquids depends on factors such as chloride content, pH, temperature, and solvent/oil content

Service Conditions

  • Installation Altitude: Must not exceed 1000 meters; for higher elevation applications, specify at the time of order for proper configuration.

  • The pump must not be used in flammable or explosive environments, nor should it handle combustible liquids.

  • Installation should be in a well-ventilated, dry, and vibration-free location.

  • Maximum ambient temperature should not exceed +40°C.

Protection Functions

  • The motor should be equipped with overload protection, phase failure protection, and overheat protection devices to prevent damage under abnormal conditions.

  • Dry-run protection is recommended to prevent mechanical seal failure in case of insufficient water supply.

  • Pressure switches or variable frequency drives (VFDs) should be used to maintain safe pressure ranges.

  • Check valves and anti-backflow devices must be installed to prevent damage caused by reverse flow after shutdown.

Selection Criteria

  • Select the pump model and number of stages based on required flow rate and head.

  • Choose appropriate wetted materials (e.g., SS304, SS316L) based on fluid temperature, pH, and chloride content.

  • Select sealing structure (mechanical seal or packing seal) based on the fluid’s corrosive properties.

  • Ensure installation space and piping layout compatibility with the horizontal configuration.

  • If the pumped liquid has higher viscosity or density than water, a higher-rated motor should be selected to meet the required shaft power.

Installation & Dimensions

Outline Drawing

LWWL Vertical Sewage Pumptypejiegoutu 1

Performance Data

No.
Name
No.
Name
1
Motor
9
Bearing Cover
2
Extended Shaft
10
Bearing
3
Bearing Seat
11
Mechanical Seal Seat
4
Pump Cover
12
Mechanical Seal
5
Oil Seal
13
Key
6
Impeller
14
Pump Wear Ring
7
Impeller Nut
15
Pump Body
8
Base

Performance Parameters

Model
Diameter
Flow Rate (m³/h)
Head (m)
Speed (rpm)
Power (kW)
Efficiency (%)
mm
(m3/h)
(M)
(r/min)
(kw)
(%)
25-7-8-0.55
25
7
8
2900
0.55
45
25-8-22-1.1
25
8
22
2900
1.1
45
32-8-12-0.75
32
8
12
2900
0.75
48
32-12-15-1.1
32
12
15
2900
1.1
 45
40-15-15-1.5
40
15
15
2900
1.5
48
40-15-30-2.2
40
15
30
2900
2.2
54
50-20-7-0.75
50
20
7
2900
0.75
51
50-10-10-0.75
50
10
10
2900
0.75
52
50-20-15-1.5
50
20
15
290
1.5
53
50-15-25-2.2
50
15
25
2900
2.2
54
50-18-30-3
50
18
30
2900
3
55
50-40-15-4
50
40
15
2900
4
55
50-25-32-5.5
50
25
32
2900
5.5
55
50-20-40-7.5
50
50
20
2900
7.5
58
65-25-15-2.2
65
25
15
2900
2.2
50
65-37-13-3
65
37
13
2900
3
57
65-25-30-4
65
25
30
2900
4
61
65-30-40-7.5
65
30
40
2900
7.5
56
65-35-50-11
65
35
50
2900
11
45
65-35-60-15
65
35
60
2900
15
65
80-40-7-2.2
80
40
7
1450
2.2
59
80-43-13-3
80
43
13
2900
3
70
80-40-15-4
80
40
15
2900
4
61
80-60-13-5.5
80
60
13
2900
5.5
67
80-65-25-7.5
80
65
25
2900
7.5
63
Model
Diameter
Flow Rate (m³/h)
Head (m)
Speed (rpm)
Power (kW)
Efficiency (%)
mm
(m3/h)
(M)
(r/min)
(kw)
(%)
100-80-10-4
100
100
10
1450
4
65
100-100-15-7.5
100
100
15
1450
7.5
68
100-80-20-7.5
100
80
20
1450
7.5
65
100-100-25-11
100
100
25
1450
11
70
100-100-30-15
100
100
30
1450
15
65
100-100-35-18.5
100
100
35
1450
18.5
68
125-130-15-11
125
130
15
1450
11
72
125-130-20-15
125
130
20
1450
15
75
150-145-9-7.5
150
145
9
1450
7.5
76
150-180-15-15
150
180
15
1450
15
69
150-180-20-18.5
150
180
20
1450
18.5
72
150-180-25-22
150
180
25
1450
22
78
150-130-30-22
150
130
30
1450
22
78
150-180-30-30
150
180
30
1450
30
78
150-200-30-37
150
200
30
1450
37
73
200-300-7-11
200
300
7
980
11
66
200-250-11-15
200
250
11
1450
15
64
200-250-15-18.5
200
250
15
1450
18.5
73
200-400-10-22
200
400
10
1450
22
75
200-400-13-30
200
400
13
14501
30
76
200-300-15-22
200
300
15
1450
22
76
200-250-22-30
200
250
22
1450
30
71
200-350-25-37
200
350
25
1450
37
71
200-400-30-45
200
400
30
1450
45
74
Model
Diameter
Flow Rate (m³/h)
Head (m)
Speed (rpm)
Power (kW)
Efficiency (%)
mm
(m3/h)
(M)
(r/min)
(kw)
(%)
250-600-9-30
250
600
9
980
30
78
250-600-12-37
250
600
12
1450
37
76
250-600-15-45
250
600
15
1450
45
73
250-600-20-55
250
600
20
1450
55
73
250-600-25-75
250
600
25
1450
75
71
300-800-12-45
300
800
12
980
45
74
300-480-15-45
300
480
15
1450
45
66
300-800-15-55
300
800
15
1450
55
73
300-600-20-55
300
600
20
1450
55
73
300-800-20-75
300
800
20
1450
75
75
300-950-20-90
300
950
20
1450
90
76
300-1000-25-110
300
1000
25
1450
110
76
300-1100-10-55
300
1100
10
1450
55
73
350-1500-15-90
350
1500
15
740
90
87
350-1200-18-90
350
1200
18
980
90
85
350-1100-28-132
350
1100
28
980
132
84
350-1000-36-160
350
1000
36
980
160
84
400-1760-7.5-55
400
1760
7.5
980
55
83
400-1500-10-75
400
1500
10
980
75
86
400-2000-13-110
400
2000
13
980
110
84
400-2000-15-132
400
2000
15
980
132
83
400-1700-22-160
400
1700
22
980
160
83
400-1500-26-160
400
1500
26
980
160
84
Model
Diameter
Flow Rate (m³/h)
Head (m)
Speed (rpm)
Power (kW)
Efficiency (%)
mm
(m3/h)
(M)
(r/min)
(kw)
(%)
400-1800-32-250
400
1800
32
980
250
82
500-2500-10-110
500
2500
10
740
110
85
500-2600-15-160
500
2600
15
740
160
84
500-2400-22-220
500
2400
22
740
220
85
500-2650-24-250
500
2650
24
740
250
85

OEM & Custom

OEM and ODM customization are available. Options include stainless-steel components, explosion-proof motors, special voltage and frequency, extended cable length, and automatic control panels. Pumps can be configured for industrial wastewater, municipal drainage, marine, or agricultural irrigation projects. Full technical support and 3D drawings are provided for international buyers.

FAQs

  1. Q: What’s the main difference between LW and WL types?
    A: LW has a vertical outlet structure, while WL is designed for higher flow and pressure applications with optimized volute and impeller profiles.
  2. Q: Can the pump handle solids or fibers?
    A: Yes, the large-channel impeller allows solids and long fibers to pass through without clogging, ensuring smooth sewage discharge.
  3. Q: What materials are available?
    A: Standard pumps use cast iron. Stainless steel or duplex alloy versions are available for corrosive environments.
  4. Q: Can it operate continuously?
    A: Yes, the pump adopts a hard-alloy double mechanical seal and F-class insulation motor for safe 24-hour continuous operation.
  5. Q: What are the installation options?
    A: The pump can be installed vertically with flange connections or equipped with automatic coupling for quick removal and maintenance.
  6. Q: Do you provide OEM labeling and voltage customization?
    A: Yes, we support OEM branding, special voltages (220V, 415V, 460V), and frequency options (50/60Hz).
  7. Q: What are the main export markets?
    A: Our LW/WL vertical sewage pumps are widely exported to Southeast Asia, Africa, the Middle East, and South America, meeting ISO and CE certification standards.