Product Overview
LW / WL Vertical Non-Clogging Sewage Pump is a vertical single-stage centrifugal sewage pump designed for handling wastewater containing suspended solids and soft particles.
It addresses clogging risk, unstable discharge, and maintenance difficulty in gravity drainage and sewage lifting systems.
It is suitable for municipal sewage treatment plants, industrial wastewater discharge, basement drainage stations, and building sewage lifting applications.
Model Designation

Applications
Typical Operating Conditions
• Municipal wastewater transfer pumping stations
• Industrial effluent discharge systems
• Underground drainage and sump pits
• Building sewage lifting systems
• Stormwater drainage networks
Engineering Advantages
• Large-flow channel impeller design reduces clogging probability
• Vertical inline structure minimizes footprint
• Direct motor-pump coupling reduces transmission loss
• Replaceable wear components simplify maintenance
• Optimized hydraulic profile improves solid handling efficiency
System Components
LW / WL Vertical Non-Clogging Sewage Pump:
The LW / WL Vertical Non-Clogging Sewage Pump mainly consists of:
• Pump casing
• Non-clog impeller
• Pump shaft
• Mechanical seal assembly
• Bearing housing
• Motor bracket
• Motor
Technical Specifications
Service Conditions
• Medium: Wastewater with suspended solids
• Solid particle size within hydraulic channel capacity
• Installation: Vertical dry-mounted configuration
Operating Conditions
Flow rate: 7 – 2650 m³/h
Head: 7 – 60 m
Power range: 0.55 – 250 kW
Speed: 290rpm /740rpm /1450 rpm / 2900 rpm
Liquid temperature: ≤ 80°C
Working pressure: ≤ 1.0 MPa
Detailed parameter tables are provided below.
Installation & Dimensions
Outline Drawing

Performance Data
|
No.
|
Name
|
No.
|
Name
|
|
1
|
Motor
|
9
|
Bearing Cover
|
|
2
|
Extended Shaft
|
10
|
Bearing
|
|
3
|
Bearing Seat
|
11
|
Mechanical Seal Seat
|
|
4
|
Pump Cover
|
12
|
Mechanical Seal
|
|
5
|
Oil Seal
|
13
|
Key
|
|
6
|
Impeller
|
14
|
Pump Wear Ring
|
|
7
|
Impeller Nut
|
15
|
Pump Body
|
|
8
|
Base
|
Performance Parameters
|
Model
|
Diameter
|
Flow Rate (m³/h)
|
Head (m)
|
Speed (rpm)
|
Power (kW)
|
Efficiency (%)
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
25-7-8-0.55
|
25
|
7
|
8
|
2900
|
0.55
|
45
|
|
25-8-22-1.1
|
25
|
8
|
22
|
2900
|
1.1
|
45
|
|
32-8-12-0.75
|
32
|
8
|
12
|
2900
|
0.75
|
48
|
|
32-12-15-1.1
|
32
|
12
|
15
|
2900
|
1.1
|
45
|
|
40-15-15-1.5
|
40
|
15
|
15
|
2900
|
1.5
|
48
|
|
40-15-30-2.2
|
40
|
15
|
30
|
2900
|
2.2
|
54
|
|
50-20-7-0.75
|
50
|
20
|
7
|
2900
|
0.75
|
51
|
|
50-10-10-0.75
|
50
|
10
|
10
|
2900
|
0.75
|
52
|
|
50-20-15-1.5
|
50
|
20
|
15
|
290
|
1.5
|
53
|
|
50-15-25-2.2
|
50
|
15
|
25
|
2900
|
2.2
|
54
|
|
50-18-30-3
|
50
|
18
|
30
|
2900
|
3
|
55
|
|
50-40-15-4
|
50
|
40
|
15
|
2900
|
4
|
55
|
|
50-25-32-5.5
|
50
|
25
|
32
|
2900
|
5.5
|
55
|
|
50-20-40-7.5
|
50
|
50
|
20
|
2900
|
7.5
|
58
|
|
65-25-15-2.2
|
65
|
25
|
15
|
2900
|
2.2
|
50
|
|
65-37-13-3
|
65
|
37
|
13
|
2900
|
3
|
57
|
|
65-25-30-4
|
65
|
25
|
30
|
2900
|
4
|
61
|
|
65-30-40-7.5
|
65
|
30
|
40
|
2900
|
7.5
|
56
|
|
65-35-50-11
|
65
|
35
|
50
|
2900
|
11
|
45
|
|
65-35-60-15
|
65
|
35
|
60
|
2900
|
15
|
65
|
|
80-40-7-2.2
|
80
|
40
|
7
|
1450
|
2.2
|
59
|
|
80-43-13-3
|
80
|
43
|
13
|
2900
|
3
|
70
|
|
80-40-15-4
|
80
|
40
|
15
|
2900
|
4
|
61
|
|
80-60-13-5.5
|
80
|
60
|
13
|
2900
|
5.5
|
67
|
|
80-65-25-7.5
|
80
|
65
|
25
|
2900
|
7.5
|
63
|
|
Model
|
Diameter
|
Flow Rate (m³/h)
|
Head (m)
|
Speed (rpm)
|
Power (kW)
|
Efficiency (%)
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
100-80-10-4
|
100
|
100
|
10
|
1450
|
4
|
65
|
|
100-100-15-7.5
|
100
|
100
|
15
|
1450
|
7.5
|
68
|
|
100-80-20-7.5
|
100
|
80
|
20
|
1450
|
7.5
|
65
|
|
100-100-25-11
|
100
|
100
|
25
|
1450
|
11
|
70
|
|
100-100-30-15
|
100
|
100
|
30
|
1450
|
15
|
65
|
|
100-100-35-18.5
|
100
|
100
|
35
|
1450
|
18.5
|
68
|
|
125-130-15-11
|
125
|
130
|
15
|
1450
|
11
|
72
|
|
125-130-20-15
|
125
|
130
|
20
|
1450
|
15
|
75
|
|
150-145-9-7.5
|
150
|
145
|
9
|
1450
|
7.5
|
76
|
|
150-180-15-15
|
150
|
180
|
15
|
1450
|
15
|
69
|
|
150-180-20-18.5
|
150
|
180
|
20
|
1450
|
18.5
|
72
|
|
150-180-25-22
|
150
|
180
|
25
|
1450
|
22
|
78
|
|
150-130-30-22
|
150
|
130
|
30
|
1450
|
22
|
78
|
|
150-180-30-30
|
150
|
180
|
30
|
1450
|
30
|
78
|
|
150-200-30-37
|
150
|
200
|
30
|
1450
|
37
|
73
|
|
200-300-7-11
|
200
|
300
|
7
|
980
|
11
|
66
|
|
200-250-11-15
|
200
|
250
|
11
|
1450
|
15
|
64
|
|
200-250-15-18.5
|
200
|
250
|
15
|
1450
|
18.5
|
73
|
|
200-400-10-22
|
200
|
400
|
10
|
1450
|
22
|
75
|
|
200-400-13-30
|
200
|
400
|
13
|
14501
|
30
|
76
|
|
200-300-15-22
|
200
|
300
|
15
|
1450
|
22
|
76
|
|
200-250-22-30
|
200
|
250
|
22
|
1450
|
30
|
71
|
|
200-350-25-37
|
200
|
350
|
25
|
1450
|
37
|
71
|
|
200-400-30-45
|
200
|
400
|
30
|
1450
|
45
|
74
|
|
Model
|
Diameter
|
Flow Rate (m³/h)
|
Head (m)
|
Speed (rpm)
|
Power (kW)
|
Efficiency (%)
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
250-600-9-30
|
250
|
600
|
9
|
980
|
30
|
78
|
|
250-600-12-37
|
250
|
600
|
12
|
1450
|
37
|
76
|
|
250-600-15-45
|
250
|
600
|
15
|
1450
|
45
|
73
|
|
250-600-20-55
|
250
|
600
|
20
|
1450
|
55
|
73
|
|
250-600-25-75
|
250
|
600
|
25
|
1450
|
75
|
71
|
|
300-800-12-45
|
300
|
800
|
12
|
980
|
45
|
74
|
|
300-480-15-45
|
300
|
480
|
15
|
1450
|
45
|
66
|
|
300-800-15-55
|
300
|
800
|
15
|
1450
|
55
|
73
|
|
300-600-20-55
|
300
|
600
|
20
|
1450
|
55
|
73
|
|
300-800-20-75
|
300
|
800
|
20
|
1450
|
75
|
75
|
|
300-950-20-90
|
300
|
950
|
20
|
1450
|
90
|
76
|
|
300-1000-25-110
|
300
|
1000
|
25
|
1450
|
110
|
76
|
|
300-1100-10-55
|
300
|
1100
|
10
|
1450
|
55
|
73
|
|
350-1500-15-90
|
350
|
1500
|
15
|
740
|
90
|
87
|
|
350-1200-18-90
|
350
|
1200
|
18
|
980
|
90
|
85
|
|
350-1100-28-132
|
350
|
1100
|
28
|
980
|
132
|
84
|
|
350-1000-36-160
|
350
|
1000
|
36
|
980
|
160
|
84
|
|
400-1760-7.5-55
|
400
|
1760
|
7.5
|
980
|
55
|
83
|
|
400-1500-10-75
|
400
|
1500
|
10
|
980
|
75
|
86
|
|
400-2000-13-110
|
400
|
2000
|
13
|
980
|
110
|
84
|
|
400-2000-15-132
|
400
|
2000
|
15
|
980
|
132
|
83
|
|
400-1700-22-160
|
400
|
1700
|
22
|
980
|
160
|
83
|
|
400-1500-26-160
|
400
|
1500
|
26
|
980
|
160
|
84
|
|
Model
|
Diameter
|
Flow Rate (m³/h)
|
Head (m)
|
Speed (rpm)
|
Power (kW)
|
Efficiency (%)
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
400-1800-32-250
|
400
|
1800
|
32
|
980
|
250
|
82
|
|
500-2500-10-110
|
500
|
2500
|
10
|
740
|
110
|
85
|
|
500-2600-15-160
|
500
|
2600
|
15
|
740
|
160
|
84
|
|
500-2400-22-220
|
500
|
2400
|
22
|
740
|
220
|
85
|
|
500-2650-24-250
|
500
|
2650
|
24
|
740
|
250
|
85
|
How to Select a Pump Model
• Determine required flow rate and system head including friction loss
• Evaluate maximum solid diameter and concentration
• Confirm installation mode (dry pit or pipeline inline)
• Check required motor speed (1450 rpm for high solid stability, 2900 rpm for compact systems)
• Verify working pressure and discharge pipe rating
Engineering Notes
• Not suitable for highly abrasive slurry with large mineral solids
• Excessive fibrous content may require cutter-type pump
• Pump must operate within designed efficiency range
• Foundation rigidity affects vibration performance
• Mechanical seal cooling must be ensured during operation
Compliance & Quality Assurance
• Factory hydraulic performance test
• Casing hydrostatic pressure testing
• Rotor dynamic balance verification
• Seal leakage inspection
• Bearing clearance inspection
• Optional third-party inspection available
Safety Notice
• Do not operate under dry-running condition
• Ensure proper grounding before energizing
• Do not exceed rated discharge pressure
• Disconnect power before maintenance
OEM & Customization
This pump series supports engineered configuration and duty-based matching. Technical adjustments can be made according to system requirements and installation conditions.
Available options include:
• Motor voltage & frequency
• Impeller material selection
• Mechanical seal configuration
• Flange standard customization
• Surface anti-corrosion coating
Configuration is determined based on duty point and project specifications.
FAQs
Q: What type of solids can this pump handle?
A: Soft suspended solids within hydraulic passage size limits.
Q: Can the pump operate under VFD control?
A: Yes, within motor rated load and cooling limits.
Q: What is the maximum allowable liquid temperature?
A: ≤ 80°C under standard configuration.
Q: What speed options are available?
A: 1450 rpm and 2900 rpm.
Q: Is it suitable for high-fiber sewage?
A: Moderate fiber content is acceptable; cutter pumps are recommended for heavy fiber loads.
Q: What sealing options are available?
A: Single or double mechanical seal configurations.
Q: What is the maximum working pressure?
A: ≤ 1.0 MPa.