QHYB-DL Constant Pressure Variable Frequency Water Supply System
Thomas Insights

QHYB-DL Constant Pressure Variable Frequency Water Supply System

November 7, 2025 Documents

型号意义 111 Product Overview   QHYB-DL Variable Frequency Constant-Pressure Water Supply System (equipped with DL vert...

Article Content

型号意义

QHYB DL Constant Pressure Variable Frequency Water Supply System type

111

Product Overview

 

QHYB-DL Variable Frequency Constant-Pressure Water Supply System (equipped with DL vertical multistage centrifugal pumps) is a new towerless water supply solution. It consists of three main parts: pump units, control system, and pressure-stabilizing booster unit. The pump units determine supply capacity; the control system ensures coordinated operation; the booster/stabilizing unit stores energy and maintains pressure to handle small water demand and normal pipeline leakage, and it is also essential for automatic control. When large water consumption occurs and the pipeline pressure drops, the pumps start automatically to supply water.

According to different working modes, QHYB-DL systems can be divided into pneumatic (pressure-tank) water supply systems and VFD (variable-frequency) water supply systems, each with its own features. They are widely used for domestic water supply, firefighting, industrial production, sprinkler systems, and other applications.

The pump is the foundation of the whole system and the key guarantee of its water-supply capability. The matching pumps are universal and can be selected with suitable flow rate and head. Depending on required flow and head, the system can operate 1–4 or more pumps in parallel. A separate booster/stabilizing small-flow pump group can switch with the main pumps within a low-flow range to improve efficiency and further reduce energy consumption.

Depending on working mode and application, the system can be configured as domestic type, firefighting type, sprinkler type, or combined domestic & firefighting type.

 

 

Selection Basis

 

The basic criteria for selecting an automatic water supply system are the designed supply flow rate and supply pressure (water head). The flow-variation pattern of the application should also be considered.

Continuous Type: Flow is rarely zero during a day, or normal pipeline leakage maintains a certain flow rate, such as pressurization systems for large hotels, restaurants, and industrial/mining enterprises.

Intermittent Type: Long low-demand periods with very small or zero flow, such as small office buildings, commercial-residential buildings, various residences, and production water use.

Flow changes within specific supply periods, seasonal variations, and regional differences in water demand should also be taken into account.

For firefighting sprinkler water supply systems, pneumatic systems are generally recommended. Since they remain in a pressure-holding state for long periods with no flow variation, they can handle normal pipeline leakage. With an additional small-flow auxiliary pump, the main pumps do not need to start during standby operation, saving energy.

Advantages of VFD Water Supply Systems: Constant-pressure water supply with adjustable pressure setpoint within a certain range; pressure accuracy is typically better than 0.02 MPa. VFD speed control is a highly efficient energy-saving method, saving about 20% on average compared with conventional pneumatic systems. In addition, VFD starting reduces inrush current and water hammer impact, and provides lower noise at low speed.

Advantages of Pneumatic Water Supply Systems: Lower overall cost, simpler control technology, convenient service, and easy maintenance.

Selection Guide

I. Pump Selection for VFD Constant-Pressure Water Supply Systems

1. Selection of Supply Head for VFD Constant-Pressure Water Supply Systems
Pump Head (m)
20
26
32
40
50
60
70
80
100
120
Supply Height (m)
10
14
18
25
32
38
46
55
72
88

 

2. Selection by Number of Households for VFD Constant-Pressure Water Supply Systems
System Flow Rate (m³/h)
6
12
18
25
36
50
Number of Households
20~30
40~60
60~100
100~150
150~200
200~300

 

System Flow Rate (m³/h)
75
100
150
200
250
Number of Households
400~500
600~1000
1000~1500
1500~2000
2000~3000

Performance Parameters

Applicable Buildings
Spray Flow (L/S)
Operating Pressure (MPa)
Applicable Building Height (m)
Recommended Model (Vertical Pump Set)
Building Type
Design Spray Density (L/min·m²)
Operating Area (m²)
Industrial Buildings
10
300
60
0.1
≤12
QHYB60-0.24-100DL-3
Industrial Buildings
10
300
60
0.1
≤24
QHYB60-0.4-100DL-3
Industrial Buildings
10
300
60
0.1
≤36
QHYB60-0.6-100DL-3
Industrial Buildings
10
300
60
0.1
≤50
QHYB60-0.8-100DL-3
Industrial Buildings
10
300
60
0.1
≤72
QHYB60-1.0-100DL-3
Industrial Buildings
10
300
60
0.1
≤100
QHYB60-1.2-100DL-3
Storage Buildings
15
300
90
0.1
≤12
QHYB90-0.24-150DL-3
Storage Buildings
15
300
90
0.1
≤24
QHYB90-0.4-150DL-3
Storage Buildings
15
300
90
0.1
≤36
QHYB90-0.6-150DL-3
Storage Buildings
15
300
90
0.1
≤50
QHYB90-0.8-150DL-3
Storage Buildings
15
300
90
0.1
≤72
QHYB90-1.0-150DL-3
Storage Buildings
15
300
90
0.1
≤100
QHYB90-1.2-150DL-3
Moderate Hazard Class
6
300
40
0.1
≤12
QHYB40-0.24-100DL-3
Moderate Hazard Class
6
300
40
0.1
≤24
QHYB40-0.4-100DL-3
Moderate Hazard Class
6
300
40
0.1
≤36
QHYB40-0.6-100DL-3
Moderate Hazard Class
6
300
40
0.1
≤50
QHYB40-0.8-100DL-3
Moderate Hazard Class
6
300
40
0.1
≤72
QHYB40-1.0-100DL-3
Moderate Hazard Class
6
300
40
0.1
≤100
QHYB40-1.2-100DL-3
Light Hazard Class
3
300
15
0.1
≤12
QHYB15-0.24-65DL-3
Light Hazard Class
3
300
15
0.1
≤24
QHYB15-0.4-65DL-3
Light Hazard Class
3
300
15
0.1
≤36
QHYB15-0.6-65DL-3
Light Hazard Class
3
300
15
0.1
≤50
QHYB15-0.8-65DL-3
Light Hazard Class
3
300
15
0.1
≤72
QHYB15-1.0-65DL-3
Light Hazard Class
3
300
15
0.1
≤100
QHYB15-1.2-65DL-3
Users may select the appropriate model based on the parameters above.

 

OEM & Custom Solutions

We offer OEM/ODM customization for system configurations, voltage (220V/380V/415V), pump selection, and control systems. Options include stainless steel manifolds, PLC/HMI touchscreen, and remote IoT monitoring. All systems are ISO9001 and CE certified for international export.

FAQs for Oversea Buyers

Q: What’s the main advantage of QHYB-DL?
A: It provides constant pressure and fully automatic operation, suitable for variable water demand systems.

Q: What type of pump is equipped in this system?
A: DL vertical multistage centrifugal pump, known for high efficiency and compact design.

Q: What’s the accuracy of pressure control?
A: ±0.02 MPa under variable frequency control.

Q: Can it be used for firefighting systems?
A: Yes, QHYB-DL can be configured for firefighting or combined domestic/fire systems.

Q: What’s the difference between variable frequency and air-pressure types?
A: Variable frequency saves up to 20% energy, while air-pressure is simpler and more cost-effective.

Q: Do you provide OEM services?
A: Yes, we offer full OEM/ODM customization including branding and packaging.

Q: Which countries use this system?
A: Exported to Southeast Asia, the Middle East, and Africa for residential, commercial, and municipal projects.