SL Corrosion Resistant Vertical FRP Chemical Pump – Updated

SL Corrosion Resistant Vertical FRP Chemical Pump – Updated

Product Overview SL Corrosion-Resistant Vertical FRP Chemical Pump is a vertical single-stage centrifugal pump manufactu...

Product Overview

SL Corrosion-Resistant Vertical FRP Chemical Pump is a vertical single-stage centrifugal pump manufactured with FRP (Fiber Reinforced Plastic) wetted components for corrosive chemical liquid transfer.

It solves corrosion failure, metal degradation, and short service life problems in acidic and alkaline fluid handling systems.

It is suitable for chemical process circulation, acid/alkali transfer, and industrial wastewater containing corrosive media.

✔ This pump is engineered for vertical immersion-type corrosion-resistant chemical transfer where metallic pumps are unsuitable.

Model Designation

SL Corrosion Resistant Vertical FRP Chemical Pump

Applications

Typical Operating Scenarios

  • Acid pickling solution circulation tanks
  • Alkali solution transfer from storage tanks
  • Chemical process sump pit vertical pumping
  • Electroplating solution circulation systems
  • Corrosive industrial wastewater lifting

Engineering Advantages

Structural Design Logic + Engineering Result

FRP molded casing and impeller provide high resistance to acid and alkali corrosion.

Vertical long-shaft structure allows immersion installation without mechanical seal exposure.

Bearing positioned outside corrosive medium reduces wear and maintenance frequency.

Simple hydraulic structure ensures stable performance under low to medium head chemical transfer duty.

Non-metallic wetted parts eliminate galvanic corrosion.

✔ The vertical FRP structural design ensures corrosion resistance, extended service life, and operational stability in aggressive chemical environments.

System Components

SL Corrosion-Resistant Vertical FRP Chemical Pump mainly consists of:

  • FRP pump casing
  • FRP impeller
  • Pump shaft
  • Shaft sleeve
  • Bearing assembly
  • Support frame / base plate
  • Discharge pipe section
  • Motor (top mounted)

Technical Data

Service Conditions

  • Corrosive acids and alkalis within FRP compatibility range
  • Solid content ≤ small non-abrasive particles
  • Continuous industrial operation

Operating Conditions

  • Flow Rate: 3.2 – 12.5 m³/h
  • Head: 12.5 – 32 m
  • Power Range: 0.55 – 4 kW
  • Speed: 2900 rpm
  • Liquid Temperature: ≤ 80°C
  • Working Pressure: ≤ 0.6 MPa

Detailed parameter tables are provided below.

Installation & Dimensions

Outline Drawing

SL Vertical FRP Chemical Pump Structure Diagram

Performance Data

1 Pump Body
2 Impeller
3 Pump Cover
4 Stationary Ring Gland
5 Mechanical Seal
6 Bracket
7 Stud Bolt
8 Motor
9 Impeller Shaft

Performance Parameters

Model
Flow Rate
m3/h
Head
m
Speed
r/min
NPSH
m
Efficiency
%
Motor Power
kW
SL25-12.5 3.2 12.5 2900 3 37 0.55
SL40-20 6.3 20 2900 3 45 1.1
SL50-20 12.5 20 2900 3 57 2.2
SL50-32 12.5 32 2900 3 47 3/4

Product Models & Specifications

Model DN D D1 D2 b n d L1 L2 H H1 D3 D4 b1 n1 d1
SL25-12.5 25 115 85 65 15 4 14 110 130 430 70 125 100 16 4 14
SL40-20 40 145 110 88 19 4 18 140 160 460 80 150 110 15 4 14
SL50-20 50 160 125 100 21 4 18 160 180 580 100 172 140 16 4 14
SL50-32 (3 kW) 50 160 125 100 21 4 18 180 200 660 120 200 165 20 4 18
SL50-32 (4 kW) 50 160 125 100 21 4 18 180 200 680 120 200 165 20 4 18

How to Select a Pump Model

Confirm chemical compatibility between medium and FRP material.

Determine required immersion depth and shaft length.

Calculate design flow and total head including vertical lift.

Verify operating temperature within ≤80°C range.

Ensure structural support meets vertical installation load requirements.

✔ Model selection shall be based on corrosion compatibility, immersion depth, and hydraulic duty calculation.

Engineering Notes

FRP material selection must correspond to chemical concentration.

Not suitable for high-abrasive slurry conditions.

Thermal expansion of non-metal materials should be considered.

Shaft alignment must be verified for long vertical configurations.

Compliance & Quality Assurance

Hydraulic performance test before delivery.

FRP material batch traceability.

Impeller dynamic balance verification.

Pressure integrity testing of casing.

Optional third-party chemical resistance verification.

Safety Notice 

Do not operate under dry-running condition.

Ensure sufficient immersion depth before startup.

Do not exceed rated temperature and pressure limits.

Disconnect power before maintenance or shaft inspection.

OEM & Customization

This pump series supports engineered configuration and duty-based matching. Technical adjustments can be made according to system requirements and installation conditions.

Available options include:

• Extended shaft length
• Different FRP resin formulations
• Motor voltage & frequency
• Explosion-proof motor configuration
• Reinforced structural support

Configuration is determined based on duty point and project specifications.
Based on duty point and project specifications.

FAQs

Q1: What chemicals are compatible with FRP construction?
Compatibility depends on acid/alkali concentration and temperature; chemical resistance chart verification is required.

Q2: Can the pump handle slurry?
Only minimal non-abrasive particles; not suitable for abrasive slurry.

Q3: What is the maximum allowable liquid temperature?
≤ 80°C.

Q4: Is mechanical seal exposed to chemical medium?
No, vertical structure avoids bottom seal exposure.

Q5: How is shaft supported in long configuration?
Upper bearing support with reinforced shaft design.

Q6: Can the pump be installed outdoors?
Yes, with proper motor protection and structural support.

Q7: What is the maximum working pressure?
≤ 0.6 MPa.