Product Overview
The YW Non-Wood Submersible Sewage Pump is developed by integrating mature technologies, with all major performance parameters conforming to the relevant national standards of similar products. This pump features a unique single-channel or double-channel impeller design, providing powerful solid handling capability within the allowed size range. It is suitable for handling fibrous materials and solid particles. The shaft sealing system consists of dual hard-alloy mechanical seals, and the main pump components are available in cast iron or stainless steel according to application requirements.
Model Designation

Key Features
-
Powerful Solid Handling Capability: The single-channel/double-channel impeller design ensures reliable transportation of sewage with solid particles and fibers.
-
Efficient Sealing System: Dual hard-alloy mechanical seals ensure zero leakage operation and improve service life.
-
Flexible Installation: Compact design, suitable for various installation configurations, no need for a pump room, reducing installation and maintenance costs.
-
Low Maintenance Requirements: Components are designed for easy replacement, reducing downtime and maintenance workload.
Engineering Overview
The YW Non-Wood Submersible Sewage Pump is specifically designed for handling wastewater containing suspended solids, sludge, and fibrous impurities. Its single-channel/double-channel hydraulic design ensures stable transportation of solid-liquid mixtures, while the sealing and structural configurations support continuous and reliable sewage operation.
Typical Applications
YW Non-Wood Submersible Sewage Pump is suitable for:
-
Factories and Commercial Facilities: Discharge of heavily polluted wastewater.
-
Residential Sewage Pump Stations: Wastewater treatment for residential areas.
-
Municipal Sewage Treatment Plants: City sewage discharge systems.
-
Civil Defense Drainage Stations: Emergency drainage systems.
-
Water Supply Auxiliary Equipment: Supporting water supply systems.
-
Wastewater Discharge for Hospitals and Hotels: Handling wastewater in medical and hotel industries.
-
Municipal Construction Sites: Wastewater treatment on construction sites.
-
Mining Equipment: Supporting wastewater treatment in mining operations.
-
Agriculture and Rural Areas: Agricultural irrigation and rural biogas pit handling.
The pump is primarily used for handling wastewater containing particles and sludge, and is also suitable for clean water and mildly corrosive media.
System Configuration
Pump Components
The YW Non-Wood Submersible Sewage Pump consists of the pump casing, single-channel or double-channel impeller, pump shaft, bearing assembly, dual hard-alloy mechanical seals (operating in an oil chamber), and a submersible motor. An optional automatic control cabinet can be provided. Wet components are available in both cast iron and stainless steel materials.
Technical Specifications
Operating Conditions
-
Ambient Temperature: ≤40°C
-
Ambient Humidity: ≤95%
-
Altitude: ≤1000 meters
-
Medium Temperature: ≤60°C
-
Medium Density: 1–1.3 (as per regulations)
-
Medium pH Range:
-
Cast Iron Version: pH 5–9
-
Stainless Steel Version: Suitable for general corrosive media
-
-
Special Requirements: If installed at altitudes above 1000 meters, please specify at the time of order for proper configuration. For specific temperature or media requirements, please provide detailed information when ordering.
Service Conditions
Regular inspection of the pump’s sealing system, impeller, and bearing assembly is recommended to ensure efficient and safe operation.
Protection Features
The YW Non-Wood Submersible Sewage Pump is equipped with multiple protection features, including overcurrent protection, temperature monitoring, and liquid level protection systems, ensuring the pump can stop operating in abnormal conditions to prevent damage to the equipment.
Selection Standards
When selecting the appropriate pump model, consider factors such as the temperature of the media, pH value, solid particle size, and the required flow and head of the pump, ensuring the selection of the most suitable configuration.
Specifications & Installation
Outline Drawing

Performance Data
| No. | Name | No. | Name |
| 1 | Motor | 12 | Oil Chamber |
| 2 | Coupling | 13 | Oil Seal |
| 3 | End Cap Connector | 14 | Pump Cover |
| 4 | Bearing Cap | 15 | Impeller Nut |
| 5 | Installation Plate | 16 | Impeller |
| 6 | Bearing Housing | 17 | Discharge Bend |
| 7 | Bearing | 18 | Pump Body |
| 8 | Extended Shaft | 19 | Wear-resistant Body |
| 9 | Support Pipe | 20 | Base |
| 10 | Bearing | 21 | Discharge Pipe |
| 11 | Mechanical Seal |
Performance Parameters
|
Model
|
Diameter
|
Flow Rate
|
Head
|
Speed
|
Power
|
Efficiency
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
25-7-8-0.55
|
25
|
7
|
8
|
2900
|
0.55
|
45
|
|
25-8-22-1.1
|
25
|
8
|
22
|
2900
|
1.1
|
45
|
|
32-8-12-0.75
|
32
|
8
|
12
|
2900
|
0.75
|
48
|
|
32-12-15-1.1
|
32
|
12
|
15
|
2900
|
1.1
|
45
|
|
40-15-15-1.5
|
40
|
15
|
15
|
2900
|
1.5
|
48
|
|
40-15-30-2.2
|
40
|
15
|
30
|
2900
|
2.2
|
54
|
|
50-20-7-0.75
|
50
|
20
|
7
|
2900
|
0.75
|
51
|
|
50-10-10-0.75
|
50
|
10
|
10
|
2900
|
0.75
|
52
|
|
50-20-15-1.5
|
50
|
20
|
15
|
290
|
1.5
|
53
|
|
50-15-25-2.2
|
50
|
15
|
25
|
2900
|
2.2
|
54
|
|
50-18-30-3
|
50
|
18
|
30
|
2900
|
3
|
55
|
|
50-40-15-4
|
50
|
40
|
15
|
2900
|
4
|
55
|
|
50-25-32-5.5
|
50
|
25
|
32
|
2900
|
5.5
|
55
|
|
50-20-40-7.5
|
50
|
50
|
20
|
2900
|
7.5
|
58
|
|
65-25-15-2.2
|
65
|
25
|
15
|
2900
|
2.2
|
50
|
|
65-37-13-3
|
65
|
37
|
13
|
2900
|
3
|
57
|
|
65-25-30-4
|
65
|
25
|
30
|
2900
|
4
|
61
|
|
65-30-40-7.5
|
65
|
30
|
40
|
2900
|
7.5
|
56
|
|
65-35-50-11
|
65
|
35
|
50
|
2900
|
11
|
45
|
|
65-35-60-15
|
65
|
35
|
60
|
2900
|
15
|
65
|
|
80-40-7-2.2
|
80
|
40
|
7
|
1450
|
2.2
|
59
|
|
80-43-13-3
|
80
|
43
|
13
|
2900
|
3
|
70
|
|
80-40-15-4
|
80
|
40
|
15
|
2900
|
4
|
61
|
|
80-60-13-5.5
|
80
|
60
|
13
|
2900
|
5.5
|
67
|
|
80-65-25-7.5
|
80
|
65
|
25
|
2900
|
7.5
|
63
|
|
Model
|
Diameter
|
Flow Rate
|
Head
|
Speed
|
Power
|
Efficiency
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
100-80-10-4
|
100
|
100
|
10
|
1450
|
4
|
65
|
|
100-100-15-7.5
|
100
|
100
|
15
|
1450
|
7.5
|
68
|
|
100-80-20-7.5
|
100
|
80
|
20
|
1450
|
7.5
|
65
|
|
100-100-25-11
|
100
|
100
|
25
|
1450
|
11
|
70
|
|
100-100-30-15
|
100
|
100
|
30
|
1450
|
15
|
65
|
|
100-100-35-18.5
|
100
|
100
|
35
|
1450
|
18.5
|
68
|
|
125-130-15-11
|
125
|
130
|
15
|
1450
|
11
|
72
|
|
125-130-20-15
|
125
|
130
|
20
|
1450
|
15
|
75
|
|
150-145-9-7.5
|
150
|
145
|
9
|
1450
|
7.5
|
76
|
|
150-180-15-15
|
150
|
180
|
15
|
1450
|
15
|
69
|
|
150-180-20-18.5
|
150
|
180
|
20
|
1450
|
18.5
|
72
|
|
150-180-25-22
|
150
|
180
|
25
|
1450
|
22
|
78
|
|
150-130-30-22
|
150
|
130
|
30
|
1450
|
22
|
78
|
|
150-180-30-30
|
150
|
180
|
30
|
1450
|
30
|
78
|
|
150-200-30-37
|
150
|
200
|
30
|
1450
|
37
|
73
|
|
200-300-7-11
|
200
|
300
|
7
|
980
|
11
|
66
|
|
200-250-11-15
|
200
|
250
|
11
|
1450
|
15
|
64
|
|
200-250-15-18.5
|
200
|
250
|
15
|
1450
|
18.5
|
73
|
|
200-400-10-22
|
200
|
400
|
10
|
1450
|
22
|
75
|
|
200-400-13-30
|
200
|
400
|
13
|
14501
|
30
|
76
|
|
200-300-15-22
|
200
|
300
|
15
|
1450
|
22
|
76
|
|
200-250-22-30
|
200
|
250
|
22
|
1450
|
30
|
71
|
|
200-350-25-37
|
200
|
350
|
25
|
1450
|
37
|
71
|
|
200-400-30-45
|
200
|
400
|
30
|
1450
|
45
|
74
|
|
Model
|
Diameter
|
Flow Rate
|
Head
|
Speed
|
Power
|
Efficiency
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
250-600-9-30
|
250
|
600
|
9
|
980
|
30
|
78
|
|
250-600-12-37
|
250
|
600
|
12
|
1450
|
37
|
76
|
|
250-600-15-45
|
250
|
600
|
15
|
1450
|
45
|
73
|
|
250-600-20-55
|
250
|
600
|
20
|
1450
|
55
|
73
|
|
250-600-25-75
|
250
|
600
|
25
|
1450
|
75
|
71
|
|
300-800-12-45
|
300
|
800
|
12
|
980
|
45
|
74
|
|
300-480-15-45
|
300
|
480
|
15
|
1450
|
45
|
66
|
|
300-800-15-55
|
300
|
800
|
15
|
1450
|
55
|
73
|
|
300-600-20-55
|
300
|
600
|
20
|
1450
|
55
|
73
|
|
300-800-20-75
|
300
|
800
|
20
|
1450
|
75
|
75
|
|
300-950-20-90
|
300
|
950
|
20
|
1450
|
90
|
76
|
|
300-1000-25-110
|
300
|
1000
|
25
|
1450
|
110
|
76
|
|
300-1100-10-55
|
300
|
1100
|
10
|
1450
|
55
|
73
|
|
350-1500-15-90
|
350
|
1500
|
15
|
740
|
90
|
87
|
|
350-1200-18-90
|
350
|
1200
|
18
|
980
|
90
|
85
|
|
350-1100-28-132
|
350
|
1100
|
28
|
980
|
132
|
84
|
|
350-1000-36-160
|
350
|
1000
|
36
|
980
|
160
|
84
|
|
400-1760-7.5-55
|
400
|
1760
|
7.5
|
980
|
55
|
83
|
|
400-1500-10-75
|
400
|
1500
|
10
|
980
|
75
|
86
|
|
400-2000-13-110
|
400
|
2000
|
13
|
980
|
110
|
84
|
|
400-2000-15-132
|
400
|
2000
|
15
|
980
|
132
|
83
|
|
400-1700-22-160
|
400
|
1700
|
22
|
980
|
160
|
83
|
|
400-1500-26-160
|
400
|
1500
|
26
|
980
|
160
|
84
|
|
Model
|
Diameter
|
Flow Rate
|
Head
|
Speed
|
Power
|
Efficiency
|
|
mm
|
(m3/h)
|
(M)
|
(r/min)
|
(kw)
|
(%)
|
|
|
400-1800-32-250
|
400
|
1800
|
32
|
980
|
250
|
82
|
|
500-2500-10-110
|
500
|
2500
|
10
|
740
|
110
|
85
|
|
500-2600-15-160
|
500
|
2600
|
15
|
740
|
160
|
84
|
|
500-2400-22-220
|
500
|
2400
|
22
|
740
|
220
|
85
|
|
500-2650-24-250
|
500
|
2650
|
24
|
740
|
250
|
85
|
OEM & Custom
We provide OEM branding, customized shaft lengths, impeller options, corrosion-resistant materials, special voltage motors, flange customization, high-wear components, engineering drainage configurations, and export-ready packaging.
FAQs
- 1. What liquids can the YW submerged sewage pump handle?
It handles sewage, sludge, slurry, wastewater, fluids with fibers, and solid-liquid mixtures. - 2. Does the pump support fully automatic control?
Yes, it can use an automatic control cabinet to start and stop based on water level. - 3. What is the maximum allowable liquid temperature?
The medium temperature should not exceed 40°C, as stated on page 3 of the PDF. - 4. How deep can the pump be submerged?
The installation depth generally ranges from 0.5 to 7 meters. - 5. Can the pump run dry?
No. Running dry may damage the mechanical seals and cause motor overload. - 6. What is the typical pH range of applicable liquids?
The pH range is 5–9, suitable for most industrial and municipal wastewater. - 7. Is OEM customization available?
Yes, including materials, power configurations, installation plates, and flange sizes.