ZH-100A Hand-Operated Fuel Metering Pump

ZH-100A Hand-Operated Fuel Metering Pump

ZH-100A Hand Fuel Metering Pump | Manual dispensing with built-in meter

  • Manual operation: Hand lever for fuel transfer.
  • Built-in meter: Resettable flow indication.
  • Nozzle option: 1-inch nozzle for on/off control.
  • Portable use: Compact for field dispensing.

Product Overview

The ZH-100A Manual Fuel Metering Pump is a manually operated fuel transfer and metering device, designed for small to medium fuel storage and dispensing applications. The pump features a compact and lightweight structure, making it easy to transport and operate. A single operator can achieve continuous fuel transfer via the manual handle. The pump is equipped with a vertical YL-25 (DN25) mechanical flow meter, which includes a zero-reset pointer for clear and direct volume indication. An optional 1-inch fuel nozzle can be installed at the outlet for on/off control, effectively preventing fuel leakage.

Key Features

  • Manual Operation: No external power required, allowing for continuous operation by a single operator.

  • Compact and Lightweight: Easy to transport and install.

  • Mechanical Flow Meter: Equipped with a zero-reset pointer for clear, direct volume reading.

  • Optional Fuel Nozzle: A 1-inch fuel nozzle can be installed for on/off control, reducing leakage risk.

  • Reliable Operation: High precision flow meter ensures accurate measurement and stable long-term use.

Engineering Overview

The ZH-100A uses a reciprocating piston principle, where the manual handle drives the piston to alternately draw and release fuel. The metering mechanism is integrated with the pump body to achieve accurate volume measurement during the transfer process. This design is ideal for environments where no electricity is required, or where simple, reliable manual control is needed.

Typical Applications

The ZH-100A is suitable for low-flow fuel transfer and metering, widely used in the following areas:

  • Small to Medium Fuel Storage: Ideal for small fuel storage and transfer.

  • Service Stations (Auxiliary Metering): Used for auxiliary fuel dispensing equipment.

  • Agricultural Machinery Stations: Provides fuel transfer and metering for agricultural machinery.

  • Industrial Plants: Suitable for internal fuel transfer and management.

  • Vehicle Fleets, Ships, and Ground Equipment at Airports: Supports fuel transfer and metering.

This pump is especially suitable for mobile, intermittent, and on-site fuel handling operations.

System Configuration

The ZH-100A Manual Fuel Metering Pump system consists of the following main components:

  • Manual Reciprocating Piston Pump Assembly

  • Vertical YL-25 Mechanical Flow Meter (DN25, with zero-reset pointer)

  • Manual Drive Handle

  • Inlet and Outlet Pipe Connection (25mm)

  • Optional 1-inch Fuel Nozzle

Components and Supply

  • Motor: High-efficiency motor to provide stable power.

  • Cutting Mechanism: Adjustable system for cutting long fibers and other materials.

  • Installation System: Simplifies installation and optimizes space usage.

  • Seal System: Offers both packing gland and mechanical seal options to suit various operating conditions.

Technical Service

  • 24/7 customer service and technical support available.

  • Regular maintenance and inspection services to extend equipment lifespan.

  • Customized solutions based on customer needs, optimizing system performance.

Operating Conditions

  • Measuring Accuracy: ±2%

  • Maximum Working Pressure: 2 kg/cm²

  • Allowable Delivery Head: 15–20 meters

  • Allowable Suction Lift: 4–5 meters

  • Reciprocation Rate: 35–45 strokes per minute

  • Applicable Media: Fuel and similar liquids

  • Operating Mode: Manual operation, manual drive

Service Conditions

  • Regular inspection of sealing performance to ensure no leakage.

  • Periodic checks and tightening of all components to ensure stability and safety.

  • Ensure the equipment operates under proper working conditions.

Protection Features

  • Overload Protection: Prevents pump damage during overload operation.

  • Temperature Control Protection: The motor stops automatically if the temperature exceeds preset limits.

  • Low Liquid Level Protection: Automatically detects liquid levels to prevent dry running.

Selection Criteria

When selecting the ZH-100A Manual Fuel Metering Pump, consider the following criteria:

  • Medium Type: Choose the appropriate pump based on the characteristics of the liquid being conveyed.

  • Installation Environment: Select a model suitable for the available installation space and environmental conditions.

  • Flow and Head Requirements: Choose the appropriate flow and head based on system requirements.

  • Energy Efficiency: Choose energy-efficient pumps to reduce operational costs.

Specifications & Installation

Outline Drawing

Structural Diagram of ZH-100A Hand-Operated Fuel Metering Pump

Performance Data

Model Diameter (mm) Flow Rate (L/min) Suction Head (m) Delivery Head (m) Metering Accuracy
ZH-100A 25 40-65 4-5 20-25 ±1%

OEM & Custom

We support OEM branding, customized color, customized hose length, upgraded sealing components, enhanced metering accuracy, optional stainless-steel construction, custom packaging, and export-ready crate solutions.

FAQs

  1. 1. What type of fuel can the ZH-100A pump handle?
    It is suitable for diesel, kerosene, gasoline, and other light oils.
  2. 2. Is the YL-25 flow meter accurate?
    Yes, with ±1% metering accuracy under normal working conditions.
  3. 3. Is the pump easy to operate?
    Yes. One person can operate it by manually reciprocating the handle.
  4. 4. Does it include a fuel nozzle?
    Yes, a 1-inch fuel nozzle is included to control fuel output.
  5. 5. What is the typical flow rate?
    Normal flow ranges between 35–65 L/min depending on operating speed.
  6. 6. Is it portable?
    Yes, the pump is compact, lightweight, and easy to move.
  7. 7. Can you provide OEM customization?
    Yes, including branding, packaging, hose options, and metering upgrades.